Life Expectancy

Start Button: Rated for 1 million presses

Electrical Specifications

Input Voltage: DC 5.9V - 12V, center positive

Maximum Current: Up to 2A (0.7A typical) @ 6V

Up to 2A (0.5A typical) @ 12V

Barrel size: 5.5 mm outer diameter, 2.5 mm inner diameter

Mechanical Specifications

Dimensions: 8" L x 4" W x 1.25" H (20.3cm L x 10.2cm W x 3.2cm H)

Weight: 12.7 oz (360 g)

Electromechanical Relays

Max Recommended Switched Voltage: DC 24V

Max Recommended Switched Current: 1A

Output Voltage To Debug Port (when configured for internal power): DC 2V-5V

Max Current To Debug Port (when configured for internal power): 0.5 A

Barrel size: 5.5mm outer diameter, 2.5 mm inner diameter

Internal Memory

1GB, 200+ programming images

Debug Ports - CYCLONE-FX-ARM

Ports A, B: 0.05" (1.27 mm) Pitch

Port C: 0.1" (2.54 mm) Pitch

Characteristic Impedance: 50 ohms (all ports)

Debug Ports - CYCLONE-FX-UNIV

Ports A, B: 0.05" (1.27 mm) Pitch

Ports C, D, E, F, G, H: 0.1" (2.54 mm) Pitch

Characteristic Impedance: 50 ohms (all ports)

International Shipping

HTS Number: 8471500150

ECCN: EAR99

Compliances/Standards

RoHS Compliant, CE Certified, FCC Certified

RED Requirements

The following standards have been applied to demonstrate FCC conformity with the RED requirements:

3.1 Health and Safety (Art. 3.1(a))

EN 62368-1:2020 - Audio/video, information and communication technology equipment

3.2 Electromagnetic Compatibility (Art. 3.1(b))

EN 301 489-1 V2.2.3 - EMC standard for radio equipment

EN 301 489-17 V3.2.4 - EMC for broadband data transmission systems

3.3 Efficient Use of Radio Spectrum (Art. 3.2)

EN 300 328 V2.2.2 - 2.4 GHz ISM band wideband transmission systems