No description provided
|
 |
|
This product covers the following Part Numbers: Cyclone MAX
|
|
Untitled Document
|
Cyclone MAX Overview
|
P&E Microcomputer Systems’ Cyclone MAX is an extremely flexible tool designed for in-circuit flash programming,
debugging, and testing of Freescale ColdFire V2/V3/V4, Power Architecture 5xx/8xx, Power Architecture 55xx/56xx (Nexus), and ARM
(MAC7xxx) microcontrollers.
By connecting to a simple BDM header on the target, the Cyclone MAX can program, test, or debug internal memory on a Freescale processor
or external flash connected to the processor's address/data bus. The processor or memory device can be mounted on the
final printed circuit board before programming.
The Cyclone MAX may be operated interactively via Windows based programming applications as well as under batch or dll commands from a PC. Once loaded with data by a PC it can be disconnected and operated manually in a completely stand-alone mode via the LCD menu and control buttons. The Cyclone MAX has over 7Mbytes of non-volatile memory, which allows the onboard storage of multiple programming images. When connected to a PC for programming or loading it can communicate via the ethernet, USB, or serial interfaces.
|
 |
The Cyclone MAX comes with intuitive configuration software, as well as easy to use automated control software.
The Cyclone MAX also functions as a full-featured debug interface, and is supported by development software from P&E, Freescale, and many other third parties.
|
|
Cyclone MAX At A Glance
|
FEATURES:
- Several Supported Architectures
Freescale ColdFire V2/V3/V4, Power Architecture (MPC5xx/8xx), Power Architecture (Nexus) (MPC55xx/56xx), and ARM (MAC7xxx) microcontrollers.
- Multiple Communications Interfaces
USB, Serial, and Ethernet interfaces.
- On-Board Storage
The Cyclone MAX may be pre-programmed with a non-volatile programming image and controlled via the LCD/Buttons or remotely from a PC. Stand-alone programming operation does not require a PC.
- Multiple Image Support
Multiple programming images may be stored in Cyclone MAX memory. Learn more about managing multiple images in our Expert's Corner.
- LCD Display
An LCD menu display, in conjunction with the status LEDs and buttons, allows stand-alone control and configuration of the Cyclone MAX.
Cyclone MAX LCD Menu
|
FUNCTIONS:
- Debugging
- Interactive Programming via a Host PC
- Stand-alone Operation
- PC Controlled Stand-alone Programming
- User Controlled Stand-alone Programming
- Third-party API
Explore Cyclone MAX functions...
WHAT'S INCLUDED:
Software
Highly intuitive configuration software, automated control software, and
interactive programming software. Supported by development software from P&E,
Freescale, and other third party vendors.
View complete list...
Power Supply/Cables
Ships with a power supply, communications interface cables, and target connection cables for a variety of microcontrollers.
View complete list...
OPTIONAL ADD-ONS:
CompactFlash ActivationExpand the Cyclone's memory by activating the CompactFlash expansion port.
Cyclone Automated Programming Package.DLL that allows control of multiple Cyclones, dynamic data programming, access to multiple programming images, and more.
|
|
Cyclone MAX In Depth
|
|
In the following sections we show you the main working modes of the Cyclone MAX. You may also view a more detailed animated demonstration of how the Cyclone MAX (Rev. A) works.
|
|
|
back to menu
Interactive Debugging *
The Cyclone MAX can be used in an interactive fashion via the Serial, USB, or Ethernet ports in order to connect to and debug a microprocessor-based target. The Serial and USB ports can be used to access the target hardware directly from the Host PC, while the Ethernet port allows the target hardware to be placed anywhere on the corporate LAN or even the Internet.
|
|
back to menu
Interactive Programming via a Host PC *
Like the Interactive Debug mode, the Interactive Programming mode allows for programming the flash of a target hardware via the Serial, USB, or Ethernet interfaces. The user can accomplish this either manually through the PROG software, or in an automated fashion through running the command line version of the programmer (CPROG). When used with the command line version of the Programmer, the Cyclone MAX can return error codes, which provide for a seamless and automated means of programming target hardware and getting pass/fail status.
|
- Host PC Command Packet Launches Programming
- Cyclone PRO/MAX Image Programmed To Target
- Cyclone Receovers Successful Result Or Error To PC
|
|
back to menu
Stand-alone Operation
Although the Cyclone MAX can be used in an interactive mode to program or debug target hardware, one of its best features is its ability to work in a pre-configured, stand-alone mode. This ability is very useful for tasks like upgrading firmware in the field, or programming target boards on production lines. In this mode, the user pre-configures the Cyclone MAX with an image that is to be programmed into the target hardware. Once the Cyclone MAX is configured, the programming process may be initiated from the Host PC or by an operator in the field. The Cyclone unit may be powered with the optional Cyclone_PowerPack, which is a lightweight and compact lithium ion battery (available separately). The combination of the Cyclone programmer and the battery pack creates a fully operational field programming setup that is lightweight, compact, and extremely portable.

back to menu
PC Controlled Stand-alone Programming
In this mode, an image has already been programmed into the Cyclone MAX. The PC launches the programming process with a simple command packet. Flash programming occurs directly from the Cyclone PRO/MAX image to the target. The result is sent back to the host computer. As part of the command packet, dynamic data such as a serial number may be added to the fixed image being programmed into the target.
|
The Cyclone PRO includes the Basic Edition of P&E's Cyclone Automated Control Package. This allows the user to automate programming with one programming image on one Cyclone. P&E also offers enhanced editions of the control package which include features like:
- Multiple Cyclone Control
- Error Detection
- Dynamic Data Programming
- Image Maintenance
For more information about the Cyclone Automated Control Package, please see the product page.

|
PC Control Of Multiple Cyclones |
User Control In Stand-Alone Mode
|
back to menu
User Controlled Stand-alone Programming
When detached from a PC, the Cyclone MAX can still operate as a stand-alone programmer. The buttons are used to launch the programming process, and the LEDs display the status of the programming operation. This is ideal for short programming runs or for field updates, where having a PC may not be desirable. In the field, the Cyclone unit may be powered with the optional Cyclone_PowerPack, which is a lightweight and compact lithium ion battery (available separately).

|
|
back to menu
Third-party API
Interactive debug, programming, and stand-alone operations can be performed using third-party tools. P&E publishes an API in the form of UNIT libraries that allow third-party developers to access the Cyclone MAX’s features via Serial, USB, or Ethernet ports. For more information, please see the INTERFACE LIBRARY ROUTINES.
back to menu
Accompanying Software and Utilities
The Cyclone Max is accompanied by the following software and utilities:
- Cyclone Max IP Setup Utility: Network IP Setup Utility which enables users to set network parameters, associate a name with each particular Cyclone MAX, and upgrade the Cyclone MAX Firmware.
- Interactive Programming Software: Allows manually-controlled programming for ColdFire V2/V3/V4, Power Architecture 5xx/8xx, and Power Architecture 55xx/56xx (Nexus) devices.
- Cyclone Max Image Creation Utility: Configures the Cyclone Max with a programming image.
- Cyclone MAX Launch Utility: May be invoked in a batch file to carry out preconfigured operations.
back to menu
Power Supply and Cables
Ships with Power Supply, DB9 Serial Cable, Ethernet Cable, USB 2.0 A/B Cable, as well as target connection cables for: Synchronous Coldfire V2/3/4 (Cable-CF-Adapter), Asynchronous ColdFire V2/3/4, Power Architecture 5xx/8xx, Power Architecture 55xx/56xx (Nexus), and ARM microcontrollers.
* The Cyclone MAX hardware supports multiple architectures and comes with flash programming software and configuration utilities for all such architectures. To use the Cyclone MAX to in-circuit debug target processors, the optional in-circuit debugging software must be purchased. See "Add-ons" at the bottom of this page to see all currently-available debug software for the Cyclone MAX.
|
| System Requirements |
Windows 2000/XP (32- or 64-bit)
Windows Vista (32- or 64-bit)
Windows 7 (32- or 64-bit)
|
|
|
| FAQs |
 |
Why are the Cyclones preconfigured with names, and what is the basis for the names? |
 |
On the ColdFire BDM cable connector, are the PST and DDATA signals used? |
 |
How do I store multiple images onto my Cyclone Pro/Max? |
 |
I have secured my MCF5213 ColdFire device and can no longer access it. How can I unsecure it? |
 |
What version of CodeWarrior supports the Cyclone Max? |
 |
I am interested in launching the CPROGxx command-line flash programmer from my own application, and reading the resultant error code. Is there some simple way to do this from a Windows based application? |
 |
I am getting an EPrivilege Exception when running P&E software. What is the problem? |
 |
When I load the ICD debugger or PROG programmer, Norton Internet Security tells me it is attempting to access the internet, Why? |
 |
When using a programming algorithm to program an external flash device, is there a simple way to test the processor's chip select configuration to make sure it's configured properly? |
 |
I try to install your software, but installation fails with this message:
There are currently 2 open applications using WinDriver. Please close all applications and press Retry. To reload WinDriver, press Cancel and reboot.
How do I solve this? |
 |
I get a Blue Screen crash when Windows attempts to install the drivers for my USB Hardware Interface when I plug it in. What can I do? |
 |
How do I update the Firmware on my Cyclone Pro or Cyclone Max? |
 |
How do I extend the ribbon cable that connects P&E's hardware to my target? |
 |
When I run the command-line programmer with a configuration file whose filename has a space in it, I get an error. What is the problem? |
 |
I am attempting to program external flash connected to my embedded processor. Either the erase, program, or show module does not work. What is the most likely sources of problems? |
 |
The connection assistant dialog indicates that my USB Multilink or Cyclone is undetected even though I have connected the hardware to my USB port. What should I do? |
 |
Once I have configured the Cyclone Max for stand-alone operation, how do I then start the programming sequence from a PC? |
|
|
|
| Downloads |
 |
64K Power Architecture 55xx Starter C Development Kit 1.22
(84158 KB)
The 64K Starter Edition of P&E's PKGPPCNEXUS software development package provides the capability to compile, debug, and flash program up to 64KB of user C code for Power Architecture 55xx devices. This software suite includes the P&E In Circuit Debugger, Flash Programmer, and WinIDE integrated environment with built-in GCC Compiler. |
 |
P&E Hardware Interface Drivers Version 9 (Windows 98/ME)
(26927 KB)
Installs P&E drivers to allow P&E applications to communicate with P&E hardware via the parallel port, PCI bus, Ethernet, Serial, and USB. This does not include the application level support which comes with the different products. This install will also work for Windows 2000/XP, but for these operating systems you should download v10 instead. |
 |
P&E Hardware Interface Drivers Version 10
(26332 KB)
Now supports Windows 7/XP/Vista 32/64 bit as well as Windows 2000/XP 32-bit. Installs P&E drivers to allow applications to communicate with P&E hardware. This does not include the application level support which comes with the different products. |
 |
64K ColdFire Starter C Development Kit
(66459 KB)
The 64K Starter Edition of P&E's PKGCFZPRO software development package provides the capability to compile, debug, and flash program up to 64KB of user C code for ColdFire devices. This software suite includes the P&E In Circuit Debugger, Flash Programmer, and WinIDE integrated environment with built-in GCC Compiler. |
 |
Cyclone MAX Single File Installation with Firmware Version 7.60
(43330 KB)
Cyclone Max Installation Software Version 7.60
Released 06/15/2009
Supports CompactFlash using MangeImages utility once activated
Please uninstall the previous version before installing the latest version.
|
|
|
|
Product |
Version |
CYCLONE_MAX |
B |
|
|
|
|
|
|
In Stock
|
CYCLONE_MAX |
Stand-Alone Programmer and Hardware Debug Interface for ColdFire V2/3/4, Power Architecture, & ARM (USB, Ethernet, Serial) |
US$899.00
Volume Pricing...
| Volume Pricing (Hide) |
| Quantity |
Price |
| 1 |
US$899.00 |
| 2 to 4 |
US$899.00 |
| 5 to 9 |
US$855.00 |
| 10 to 24 |
US$810.00 |
| 25 or more |
Contact us |
|
|
|
|
In Stock
|
|
ColdFire Development Package (Cyclone MAX Interface and Software Package) |
US$1,249.00 |
 |
|
In Stock
|
|
ColdFire Development Package w/ GNU C Compiler (Cyclone MAX Interface and PKGCFZ_PRO) |
US$1,599.00 |
 |
|
In Stock
|
|
Power Architecture (Nexus) Development Package (Cyclone MAX and PKGPPCNEXUS Software Package) |
US$1,599.00 |
 |
|
In Stock
|
|
Power Architecture 5xx/8xx BDM Development Package (Cyclone MAX and PKGPPCZ Software Package) |
US$1,349.00 |
 |
|
|
In Stock
|
|
Rechargeable Lithium Ion PowerPack for Cyclone Pro and Cyclone Max |
US$159.00 |
 |
|
In Stock
|
|
Compact Flash License and Flash Card Package |
US$249.00 |
 |
|
In Stock
|
|
Power Architecture 5xx/8xx In-Circuit Debugger Software |
US$299.00 |
 |
|
In Stock
|
|
Cyclone Automated Control Package: Professional Edition |
US$299.00 |
 |
|
In Stock
|
|
ColdFire Library Routines (1 Developer, 5 Machine, Windows) |
US$299.00 |
 |
|
In Stock
|
|
Cyclone Automated Control Package: Enterprise Edition |
US$999.00 |
 |
|
In Stock
|
|
ColdFire In-Circuit Debugger Software |
US$399.00 |
 |
|
In Stock
|
|
Power Architecture 55xx/56xx Library Routines (1 Developer, 5 Machine, Windows) |
US$299.00 |
 |
|
In Stock
|
|
Power Architecture 5xx/8xx Library Routines (1 Developer, 5 Machine, Windows) |
US$299.00 |
 |
|
In Stock
|
|
Compact Flash Activation License. Compact flash card available separately. |
US$229.00 |
 |
|
|
© 2010 P&E Microcomputer Systems